Discover

Discover

Notes
You will need the Discover Lynk device to adapt the battery’s AEBus to CAN Bus for use with the Sol-Ark. The Lynk will need the proper adapter for the Sol-Ark’s pin configuration (Part number 950-0016-SLRK). Communications with this battery will require a custom cable for outdoor-rated units only.

Custom Cable
Insert the included RJ45 splitters into the AEBus port of each Discover Battery.
Connect and link each battery to the next in a chain using RJ45.
Connect either end of the chain of the batteries to the AEBus RJ45 port on the Lynk.
Connect the 12V power supply to one of the batteries and plug it into the other end of the chain using an RJ45 cable.
Connect the Edge Card’s RJ45 port to the CAN Bus port of the Sol-Ark.

For outdoor-rated units only, create a custom RJ45 cable that connects pins four (4) (solid blue) and five (5) (white-blue) through to the same pins
on the inverter and connects pin two (2) (solid orange) on the LYNK side to pin six (6) on the inverter.
Use standard ethernet cable for indoor-rated units – no custom cable is needed.

BMS 00
Program the inverter with this battery's appropriate charge/discharge settings.
Enable “BMS Lithium Batt” and set its value to “00.”

BMS Error Stop Option

To turn off the system fault on the loss of battery communications, turn on “BMS_Err_Stop” 
    • Related Articles

    • Pylontech Pelio

      https://pylonwebs3.s3.amazonaws.com/upload/2024/09/25/RESS-Installation%20Manual-Pelio%205PMPA08-00124_20240925122854A042.pdf Set the 'StartV' for the voltage at which charging should initiate. Float V = 55.7 V Absorption V = 56.0 V Equalization V = ...
    • Residential Basic Programming Guide

      BASIC PROGRAMMING GUIDE SYSTEM WORK MODES AND TIME OF USE FOR SINGLE INVERTER INSTALLATIONS
    • Powersync

      Communications Installation and Setup Instructions 877-459-4591 support@powersyncenergy.com Manual Link: netorgft3957589.sharepoint.com/Shared Documents/Forms/AllItems.aspx?id=%2FShared Documents%2FLFP - Low Voltage Module%2FManuals%2FLFP-LV Module – ...
    • SOK

      Notes Connect all batteries together with the provided RJ45 cables using the “RS485B/RS485C” ports. Either port can be used for each battery. Up to 15 batteries can be connected in parallel. Binary Numbering Set the DIP switches such that the battery ...
    • 15k.21 Generators

      Wiring to the GEN or GRID port There are two ways to interconnect a generator to a Sol-Ark: via the GRID or GEN port. The GEN port is the easiest place to land generators onto a Sol-Ark system. Wiring to the GEN port avoids the need for an automatic ...